OP-300
OP-300-SM-B(1310/1550nm, 30/28dB,single mode,100KM
OP-300-SM-C(1310/1550nm, 32/30dB, single mode,120KM
OP-300-MM(850/1300nm), 21/19dB,Multi mode,6/40KM
Features
5.6-Inch outdoor-enhanced touchscreen, 7.4V/4.4Ah Lithium battery
Event Dead zone as lower as 1.5meter
Combined multi-dynamic range and wavelengths
Muti measurement mode, support Touching LCD and pressing keys
Warning function could prevent OTDR module from being damaged by optical signal in fiber.
Realtime measuring function, convenient to monitor the splicing process
Integrated 10mw Visual Fault Locator
Support English/ Chinese input, adopts friendly input interface, totally simulate the computer keyboard input
Integrated with 8GB internal memory, more than 80,000 groups curve storage
PC remote access and control function is available, which support the printing work of the measurement report
Main Function
Automatic Measurement Mode:Operators do not need to choose the test distance and pulse width, the tester will automatically judge the length, and choose suitable dynamic range as well as pulse width to complete the work; The storage of event trace can be saves manually or automatically which will be convenient for data analysis
Multiple Wavelengths Measurement Mode:In order to use different wavelengths to execute the loss calculation in one fiber, we can choose duplex wavelengths test mode from parameter settings, the tester will switch wavelengths automatically
Multiple Trace Analysis:Simultaneous display 4 traces, operators can compare the traces and make analysis of any ones among the traces
Online Test:This will protect the test instruments and equipment
Duplex Operation Mode:Pure operation through touch screen ; or pure operation through the pressing keys
Data Analysis: Save and generator standard trace file(. Sor), more than 20000 groups storage capacity:
Print the analysis report and traces which make the acceptance or work easily
Specifications
Pulse Width | (SM 1310/1550NM) 5ns 10ns 20ns 50ns 100ns 500ns 1μs 2μs 5μs 10μs : (MM 850/1300NM) 5ns,10ns,20ns,50ns,100ns,500ns,1us |
Distance Range | (SM 1310/1550NM) Dead zone test, 1.3km, 2.5km, 5.0km, 10km, 20km, 40km, 80km, 120km, (MM 850/1300NM):100m,400m,1.3km,2.5km,5km,10km,20km,40km |
Sampling Resolution | Minimum 0.05m |
Sampling Point | 128,000 |
Linearity | ≤0.05dB/dB |
Loss Threshold | 0.01dB |
Loss Resolution | 0.001dB |
Distance Resolution | 0.01m |
Distance Accuracy | ±(1m+measuring distance×3×10 +sampling resolution) |
Data Storage | 20000 groups of curve |
VFL | 10mW,CW/2Hz |
Interface | 3 USB ports(Type A×2,Type B×1) |
Display | 5.6 inch TFT-LCD, Touching screen |
Battery | 7.4V/4.4Ah lithium battery , support 8 hours continuous working |
Working conditions | Working Temp:-10℃~+50℃;Storage Temp:-20℃~+70℃;Humitity :≤95%(non-dew) |
Dimensions/Weight | 253×168×73.5mm / 2kg(include battery) |
Packing list | Straps; Adaptor; Lithium battery; FC connector; USD Cable; User Guide; CD; softbag; cleaning cotton |